Brand Name: | Sinuo |
Model Number: | SN1007 |
MOQ: | 1 |
Price: | Customized |
Payment Terms: | T/T |
Supply Ability: | 30 Sets / Month |
IEC 62196 New Energy Vehicles Plugs And Sockets Cable Pull And Torque Test Equipment
Complied Standards & Clauses
IEC 62196-1 Ed.4CDV 2020 clause 25.3 Figure 17 and table 11,
IEC60309-1: 2012 clause 23.3, etc.
Technical Parameters
Operation Method | Button operation |
Drive Mode | Motor and cylinder |
Pull Force Weights |
50N*1, 60N*1, 110N*1, 40N*2,110N*1 Can achieve 160N, 200N, 240N, 250N,500N |
Torque Weights |
6N*1, 7N*1, 12N*1, 15N*1, 23N*1, 110N*1 Can achieve 0.6N.m, 0.7N.m, 1.2N.m, 1.5N.m, 2.3N.m, 11N.m |
Torque Arm | 100mm(Ф200mm) |
Pull Frequency | 1cycle/s |
Pull Cycles | 1-9999 cycles, can be preset, default 100 cycles |
Torque Applied Time | 0-99H59M59S, can be preset, default 1min |
Fixture | One set of universal fixture |
Equipment Overview
Samples and Restrictions: Electric vehicle charging interfaces (plug, socket-outlets, vehicle connectors), industrial purpose plugs, socket-outlets and couplers.
Application: To test the vehicle plugs, and socket-outlets, connectors to withstand the specified pull force and torque.
Test Principle: Pull is realized by single-phase speed-regulating motor to drive the eccentric mechanism, the motor speed is adjustable, to ensure the accurate time for each pull force applied; torque is achieved using cylinders, trays, weights and time relays.
Structure: Pull force is applied through weights, torque is applied through weight and torque arm. The preset counter and the digital display time relay are used to control the cycles of pull test and the time of the torque test. The test cycles or the test time reaches the preset value, the apparatus will automatically stop testing. The maximum allowable displacement of the flexible cable of the plugs, socket-outlets and vehicle connectors shall not exceed the standard requirement after the test.
Use Environment: Power supply: AC220V±10%,50/60Hz, 1KW, or match client’s local power supply requirements
Working temperature 0-40°C, humidity 30%-90%
Dimensions: about W1600*D500*H1135mm
Weight: about 100kg