Brand Name: | Sinuo |
Model Number: | SN886-12m³ |
MOQ: | 1 |
Payment Terms: | T/T |
Supply Ability: | 10 Sets Per Month |
IEC 60068-2-1 Walk-in Constant Temperature and Humidity Test Chamber 12m³
Complied Standards & Clauses
Conforms to IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-3, and IEC 60068-2-30,etc., etc.
Product Overview
Complied Standard: IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-3, and IEC 60068-2-30,etc.
Application: This equipment is suitable for environmental simulation reliability tests such as high and low temperature constant and gradual changes, cycle tests, etc. for various electrical and electronic products and other products, components and materials.
Safety test limitations:
A) Testing and storage of flammable, explosive and volatile substance samples.
B) Testing of corrosive substance samples and testing or storage of biological samples.
C) Testing and storage of samples of strong electromagnetic emission sources.
Technical Parameters
Volume and dimensions | |
Effective volume | 12m³ |
Inner chamber size | 3000 mm*2000 mm*2000mm(W*H*D) |
Outer chamber size |
Approximately 3700 mm*2200 mm*2300 mm(W*H*D) Warm reminder: Please refer to the three views of the final design for external dimensions. |
Container size |
The inner dimensions of the 40HQ container are 12.032m (L)*2.352m (W)*2.69m(H) The door is 2.55M high (it will be extra wide after being packed with wooden boxes) |
Performance | |
Cooling method | Water cooling |
Temperature range | -40°~ 150℃ |
Humidity range | 20%RH~95%RH |
Temperature/humidity fluctuation | ±2℃/±2.0%RH |
Temperature analysis accuracy | 0.01℃ |
Humidity analysis accuracy | 0.01RH |
Temperature uniformity | ≤2℃ |
Humidity uniformity | < 75%RH:±3%RH >75%RH±5%RH |
Heating rate | ≦3.0℃/min (non-linear, no load) |
Cooling rate | Average 1.0℃/min (non-linear, no load) |
Load condition | No load |
Complied Standards |
IEC 60068-2-1 Test A: Low-temperature test method. IEC 60068-2-2 Test B: High-temperature test method. IEC 60068-2-3 Test Ca: Constant damp heat test method. IEC 60068-2-30 test Db: alternating damp heat test method. |
Temperature and humidity diagram |
PS: Standard humidity 20%~95%HR |
Structure and materials | |
Outer chamber material | Using high-grade hot and cold steel plates with non-static Nano-baking paint |
Inner chamber material | SUS304 stainless steel plate |
Insulation material | High temperature resistant and fireproof rigid polyurethane foam |
Door frame sealing strip | Silicone rubber sealing strip |
Chamber door | The outward-opening double doors are equipped with electric heating devices and overflow ditches inside the door frames and edges of the door panels. |
Electric heating glass observation window |
Quantity: 2 pieces Location: On the door of the laboratory (or at the customer's designated location) Form: 3-layer vacuum tempered glass with built-in anti-fog heating element |
lighting | High and low temperature-resistant explosion-proof energy-saving lamps |
Pressure balance port | All-aluminum alloy 4-group self-restoring pressure window with anti-sweat line |
Load-bearing | Chamber load-bearing: 1000KG |